{"id":987,"date":"2023-02-04T15:48:49","date_gmt":"2023-02-04T14:48:49","guid":{"rendered":"http:\/\/46.62.225.216\/?page_id=987"},"modified":"2024-02-02T12:56:09","modified_gmt":"2024-02-02T11:56:09","slug":"n287tb-oxygen-peculiarities","status":"publish","type":"page","link":"https:\/\/foxromeo.net\/?page_id=987","title":{"rendered":"N287TB oxygen peculiarities"},"content":{"rendered":"<p><span style=\"font-family: helvetica, arial, sans-serif;\">N287TB has a built in Oxygen system ! \u00a0The advantage is that you can monitor it on the MFD and the reservoir is bigger than a portable<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">However like all oxygen systems there is a huge amount of waste. Using cannulae to some extent slows up wastage but N287TB has an additional regulator which allows it to connect to a Mountain High 2 place pulse Oxymiser.\u00a0 Remember that the built in system is a &#8216;Precision Flight&#8217; product. Of course no two suppliers of systems talk to each other, but the kit in N287TB is recognised as a good way of doing things.<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The Mountain High OxyMiser is recognised as one of the best pulse oxygen delivery systems and it is good to get it to &#8216;talk&#8217; to the Precision Flight built in system. The Built in system might give some 4-6 hours for 2 people but with the pulse system this can be as much as 16 hours<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\"> Also to avoid tubes all over the place I have made one section which connects either\u00a0<\/span><\/p>\n<ul>\n<li><span style=\"font-family: helvetica, arial, sans-serif;\">the oxyboom on the headset (personalised for John and Maggie)\u00a0<\/span><\/li>\n<li><span style=\"font-family: helvetica, arial, sans-serif;\">a cannula\u00a0<\/span><\/li>\n<li><span style=\"font-family: helvetica, arial, sans-serif;\">the blue face masks with microphone (intended for &gt;18,000ft<\/span><\/li>\n<\/ul>\n<p><span style=\"font-family: helvetica, arial, sans-serif;\">the tubing from any one of these terminates in a bayonet fitting which must then be connected to the length of tubing which connects to the Oxymiser which itself has a female bayonet fitting. In this way cannulae, oxybooms or microphone face masks can be swapped out<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The non bayonet end of this connector length end in a straight relatively hard bit of plastic tube faintly coloured blue. This should be pushed into one of the blue holes on th<img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-988 alignleft\" src=\"http:\/\/46.62.225.216\/wp-content\/uploads\/2023\/02\/MHO2D2-300x171.png\" alt=\"\" width=\"300\" height=\"171\" srcset=\"https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHO2D2-300x171.png 300w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHO2D2-100x57.png 100w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHO2D2-150x85.png 150w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHO2D2-200x114.png 200w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHO2D2-450x256.png 450w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHO2D2.png 552w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>e OxyMiser itself. With your fingers press down on the blue collar of the OxyMiser and the plastic tube should slide in smoothly. ditto for taking it out<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The length of tune with the regulator has a fitting compatible with the Cirrus Oxygen ceiling fitting. Carefully push this steel\/rubber connector into one of the ceiling sockets. There are 4 for 4 place oxygen but it doesnt matter which one you put it in\u00a0<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The other end of this tube also ends in a faintly red coloured bit of hard plastic and is inserted in the same way as the blue connectors to the Oxyboom or Cannula<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">There is a blue connector with suitable bayonet in the pockets by your ankle &#8211; pilot on left passenger on right.\u00a0<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The regulator length can be found in the passenger side right front pocket\u00a0<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The oxymiser lives in centre console and is powered by 3 AA batteries. It is switched on by turning the knob to an appropriate setting.<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The yellow settings are for flight levels and face mask using continuous flow. The D settings are &#8216;on demand&#8217; Teh N is for &#8216;Now&#8217; or &#8216;nightime&#8217;<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">connection to manual here <a href=\"http:\/\/46.62.225.216\/5MD20-0003-00Rev-1-MH-EDS-2G-User-Manual.pdf\">Mountain High O2D2\u00a0\u00a0<\/a><\/span><\/p>\n<p>\u00a0<\/p>\n<p><span style=\"font-family: helvetica, arial, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-989 alignleft\" src=\"http:\/\/46.62.225.216\/wp-content\/uploads\/2023\/02\/MHconnector-186x300.png\" alt=\"\" width=\"108\" height=\"174\" srcset=\"https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-186x300.png 186w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-636x1024.png 636w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-768x1237.png 768w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-954x1536.png 954w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-1271x2048.png 1271w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-100x161.png 100w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-150x242.png 150w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-200x322.png 200w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-300x483.png 300w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-450x725.png 450w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-600x967.png 600w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/MHconnector-900x1450.png 900w\" sizes=\"auto, (max-width: 108px) 100vw, 108px\" \/><\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">On the left is a cannula but not one with the bayonet fitting.\u00a0 This one, simply don and then push the blue end into the oxymiser<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\">The only point in breaking the pipe an dputting in a bayonet fitting is that Masks, oxybooms an dcannula are all interchangeable\u00a0<\/span> <span style=\"font-family: helvetica, arial, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-991\" src=\"http:\/\/46.62.225.216\/wp-content\/uploads\/2023\/02\/Image4-219x300.jpg\" alt=\"\" width=\"219\" height=\"300\" srcset=\"https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-219x300.jpg 219w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-747x1024.jpg 747w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-768x1053.jpg 768w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-1121x1536.jpg 1121w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-1494x2048.jpg 1494w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-100x137.jpg 100w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-150x206.jpg 150w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-200x274.jpg 200w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-300x411.jpg 300w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-450x617.jpg 450w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-600x822.jpg 600w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-900x1233.jpg 900w, https:\/\/foxromeo.net\/wp-content\/uploads\/2023\/02\/Image4-scaled.jpg 1868w\" sizes=\"auto, (max-width: 219px) 100vw, 219px\" \/><\/span><\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"<p>N287TB has a built in Oxygen system ! \u00a0The advantage is that you can monitor it on the MFD and the reservoir is bigger than a portable However like all oxygen systems there is a huge amount of waste. Using<span class=\"ellipsis\">&hellip;<\/span><\/p>\n<div class=\"read-more\"><a href=\"https:\/\/foxromeo.net\/?page_id=987\">Read more <span class=\"screen-reader-text\">N287TB oxygen peculiarities<\/span><span class=\"meta-nav\"> &#8250;<\/span><\/a><\/div>\n<p><!-- end of .read-more --><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"nf_dc_page":"","footnotes":""},"class_list":["post-987","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/foxromeo.net\/index.php?rest_route=\/wp\/v2\/pages\/987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/foxromeo.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/foxromeo.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/foxromeo.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/foxromeo.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=987"}],"version-history":[{"count":3,"href":"https:\/\/foxromeo.net\/index.php?rest_route=\/wp\/v2\/pages\/987\/revisions"}],"predecessor-version":[{"id":1210,"href":"https:\/\/foxromeo.net\/index.php?rest_route=\/wp\/v2\/pages\/987\/revisions\/1210"}],"wp:attachment":[{"href":"https:\/\/foxromeo.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}